E-ABLE POWER / COMMERCIAL ENERGY STORAGE

GCB-E241Storage Cabinet

GCB-E241 125kW/241kWh commercial storage system delivering high throughput for peak shaving, backup and solar self-use. Multiple cabinets parallel to MW scale for large facilities, microgrids and EV charging.

>
E-ABLE POWER — PRODUCT DATASHEET
COMMERCIAL ENERGY STORAGE SOLUTIONS
C&I INDUSTRIAL ESS125kW / 241kWhFULLY CONFIGURABLE

GCB-E241 Series | All-in-One C&I BESS Cabinet

GCB-E241 Commercial & Industrial Energy Storage System

A high-capacity 125kW/241.15kWh all-in-one BESS cabinet using fifteen 51.2V/314Ah LFP battery packs in series. The system integrates air cooling and fire protection in a single IP54 enclosure (1300×1260×2375mm, 2500kg without PCS). Engineered for peak shaving, backup power, solar self-consumption, microgrid and EV charging support. Every system is configured to the approved site requirements.

GCB-E241 125kW 241.15kWh all-in-one LFP BESS cabinet

Key Specifications at a Glance

AC Power 125kW — Three-Phase Four-Wire AC380, 50Hz, 189A Nominal Energy 241.15kWh
Battery Cells Grade A LFP — 3.2V 314Ah Options Cycle Life 6,000 cycles at 90% DOD
Architecture All-in-One — Air Cooling + Integrated Fire Protection Round-Trip Efficiency ≥90% System-Level
Enclosure IP54 — 1300×1260×2375mm — 2500kg Without PCS Battery Voltage 768V — Range 672–864V
Communication RS485 / CAN Operating Temp. -20°C to 50°C; 0–95% RH; altitude <2,000m
Certifications Project-specific compliance documentation available on request Warranty 10 Years

Core Engineering Advantages

Ultimate Cycle Longevity

LFP 314Ah battery packs deliver 6,000 cycles at 90% DOD. The final operating profile is confirmed per project.

125kW High-Rate Throughput

125kW rated charge/discharge power at AC380 three-phase four-wire, 50Hz and 189A; ≥90% system efficiency.

Air Cooling

Air cooling incorporates refrigeration, ventilation and heating. Rated operating environment: -20°C to 50°C, 0–95% RH, altitude <2,000m.

Integrated Protection & Communication

Integrated fire-protection system and RS485 / CAN communication for seamless EMS/SCADA integration.

System Electrical Performance

Rated voltage: 768V; operating range: 672–864V; total harmonic distortion: <3%; power factor: -1 to 1.

High Energy Density

The cabinet measures 1300×1260×2375mm and weighs 2500kg without PCS. Noise level is ≤75dB.

GCB-E241 Technical Specifications

Category Parameter Specification
System Config Model GCB-E241
Rating 125kW / 241.15kWh All-in-One Energy Storage Cabinet
Application C&I Peak Shaving, Microgrid, Backup Power, Solar Self-Consumption, EV Charging Support
Battery Core Cell Specification Grade A LiFePO4 (LFP) — 3.2V 314Ah Prismatic
Energy Capacity 241.15 kWh — 15 × 51.2V / 314Ah packs in series
DoD / Cycle Life 90% DoD / ≥ 6,000 Cycles at 25°C, 0.5C
Round-Trip Efficiency ≥ 90% System-Level
Inverter PCS Rated Power 125 kW — Three-Phase Four-Wire AC380, 50Hz
Output Current 189 A
Operating Modes Project-Specific Operating Interface (Configurable per Project)
Physical Data Dimensions / Weight 1300 × 1260 × 2375 mm / 2500 kg (Without PCS)
Ingress Protection IP54 — Outdoor Rated
Certifications Project-specific compliance documentation available on request
Operating Temp. -20 °C to 50 °C; 0–95% RH; altitude <2,000m; air cooling; noise ≤75dB

Table 1.0 — GCB-E241 technical specifications. System configuration, inverter selection, operating interface and project-specific compliance documents are confirmed per order. 10-year warranty.

Frequently Asked Questions

Q: What battery configuration does the GCB-E241 use?

The GCB-E241 uses fifteen 51.2V/314Ah LFP battery packs in series, providing 241.15kWh nominal energy at 768V. The final system configuration is validated against the project load profile and autonomy requirement.

Q: Can the GCB-E241 support EV charging infrastructure?

Yes. The GCB-E241's 125kW PCS is well-suited for EV charging hub buffering — storing energy during off-peak periods and discharging during charging demand spikes to avoid expensive grid upgrades. In a typical configuration, one GCB-E241 can buffer approximately 3–4 simultaneous 30kW DC fast chargers or 15–20 Level 2 AC chargers during peak periods. The system can also integrate with solar carports for a fully renewable charging solution. Actual sizing depends on charger count, session patterns, and grid capacity — contact engineering for a site-specific analysis.

Q: What customization options are available for the GCB-E241?

The GCB-E241 is configurable to project requirements. Options subject to project volume include: inverter selection (Solis, Growatt, Goodwe or DEYE), cabinet color and OEM branding, communication interface (RS485 / CAN), and destination-market compliance requirements. Contact E-Able Power with your specification for a customized proposal within 2–3 business days.

Q: What site preparations and maintenance does the GCB-E241 require?

Pre-installation: reinforced concrete pad (~3,500kg load + safety factor), minimum 1.2m clearance on all service sides, AC cable routing from main distribution panel, and Ethernet/4G for remote monitoring. Maintenance is minimal — no water topping, no electrolyte replacement, air-cooling components require routine inspection. Annual inspection includes a visual check of enclosure seals, air-cooling service, bolt torque verification, and battery SoH reading via the BMS interface. Remote commissioning support included; on-site engineer available for projects above 500 kWh.

Factory: Dongguan, Guangdong, China. Project-specific compliance documentation available on request. 10-year warranty.

GCB-E241 FAQ

What is the GCB-E241's rated output or capacity?

The GCB-E241 provides 125kW three-phase four-wire AC380 and 241.15 kWh of energy.

What battery technology does the GCB-E241 use?

It uses Grade A LFP 3.2V 314Ah. It is rated for 6,000 cycles at 90% DOD.

What voltage and configuration does the GCB-E241 support?

It operates at 768V (range 672–864V).

Is the GCB-E241 protected against dust, water and impact?

Rated IP54. It is built for outdoor use.

How is the GCB-E241 managed in different conditions?

Operating range -20°C to 50°C.

What control and communication does the GCB-E241 support?

Communication via RS485 / CAN.

Can the GCB-E241 be configured for a project?

Yes — configuration can be adapted for a project. Contact us with your site and energy or lighting requirements for sizing and a quotation.

Configure your GCB-E241 energy storage system

Every GCB-E241 is configured to your site — system configuration, inverter selection, operating interface and protection design are confirmed per project. Send your load profile and requirements for a complete BESS technical proposal within 2–3 business days.